Acceptance of Energy Storage Power Station

In the promotion of the new round of energy revolution, energy storage, as the core technology of energy transformation, plays a vital role in electric storage capacity and acts as a "reservoir".


New energy storage is an important technology and a basic equipment for building a new power system, an important support for achieving the goal of carbon peaking and carbon neutralization, and an important field for promoting new domestic energy formats and seizing a new international strategic highland. Since the 13th Five Year Plan, China's new energy storage industry has been in the transition stage from R&D demonstration to the early stage of commercialization. Substantial progress has been made in technical equipment R&D, demonstration project construction, business model exploration, policy system construction, etc. The market application scale has steadily expanded, and the supporting role of the energy transformation has initially emerged.

 

NOA has been committed to the test and inspection service of the energy storage power station. The energy storage power station is famous for its high risk and high return. The research shows that the energy storage power stations in the domestic market are generally in the form of electrochemical energy storage, that is, the cascade utilization of batteries. Through professional third-party testing, it can avoid some dangerous situations and meet the national standards; It can also fully understand the performance parameters and quality of the energy storage power station. The main modes of the energy storage system include the energy storage system configured on the DC side of the power supply, the energy storage system configured on the AC side of the power supply, and the energy storage system configured on the load side. NOA will develop different detection schemes for different modes. The energy storage power station is dangerous. The battery heats up quickly, the temperature is high, the heat is out of control and easy to spread, the gas is explosive and toxic. Therefore, the energy storage power station needs to optimize the design link, standardize the safety standards of the power station, improve the electrochemical safety management system, and do a good job of detection and early warning in advance.

 

 

Service Content

One. Service content

1. Overall inspection of site conditions

2. Inspection of civil engineering and supporting facilities

3. Operation management system inspection

4. Inspection of energy storage equipment (battery part)

5. Inspection of energy storage equipment (grid connection part)

6. Parameter and performance test

7. Inspection and detection of power supply and distribution system

8. Inspection of accessory system

 

 

Two. Reference Standard

1. GB/T 36276-2018 Lithium ion battery for electrical energy storage

2. GB/T 34133-2017 Testing code for power converter of electrochemical energy storage system

3. GB/T 34120-2017 Technical specification for power conversion system of electrochemical energy storage system

4. NB/T 31016-2011 General specification for power control system of battery energy storage system

5. GB/T 34131-2017 Technical standard for battery management system of electrochemical energy storage station

6. GB 51048 2014 Design code for electrochemical energy storage station

7. GB/T 36558-2018 General technical requirements for electrochemical energy storage system in power system

8. GB/T 34120-2017 Technical specification for power conversion system of electrochemical energy storage system

9. GB/T 36548-2018 Test specification for electrochemical energy storage system connected to power grid

10. GB/T 36547-2018 Technical rule for electrochemical energy storage system connected to power grid

 

Service Process

Q&A
 
Is the test standard only in accordance with the (China) national standard?
Domestic energy storage power stations shall comply with relevant national standards, and the test standards of battery chips can be conducted in accordance with European IEC and American UL.
Does the battery of the energy storage station need to be tested?
Energy storage power stations generally use power batteries for cascade utilization. Generally speaking, testing is required after the energy storage system is integrated.
Is the on-site acceptance test of the energy storage plant necessary?
In April 2021, the Jimei Dahongmen 25MWh DC photovoltaic storage and charging integrated power station project located in Fengtai District, Beijing, exploded, causing death of two firefighters. The power station without on-site detection has a high degree of danger, and there will be more incentives for explosion.
Is the tested and accepted energy storage power plant safe?
No. The inspection and acceptance can ensure that the construction design and construction specifications, as well as the relevant parameters of the energy storage battery are normal, and eliminate technical safety hazards.
Our Advantage
Authoritative Qualification
NOA has been approved by Certification and Accreditation Administration of the People’s Republic of China(CNCA)(CNCA-R-2002-051), and has obtained qualification of China Inspection Body and Laboratory Mandatory Approval (CMA),and has passed the multiple approvals of China National Accreditation Service for Conformity Assessment (CNAS), International Accreditation Service (IAS), United Kingdom Accreditation Service (UKAS), Joint Accreditation System of Australia and New Zealand (JAS-ANZ). NOA has been approved by State Administration for Market Regulation of China, and has been recognized as inspection and testing institution of China's special equipment, as well as the qualification of China's national equipment supervision and engineering supervision. NOA-DCI is the notified body of the CE directive of the European Commission. NOA has been recognized by the International Electrotechnical Commission (IECQ) by obtaining Electronic Component Quality Assessment System. It is also a national inspection and assessment notified body of import and export commodity in China.NOA is a high-tech enterprise in Shanghai.
Improve Performance, Realize Asset Value Appreciation, and Service Throughout the Entire Value Chain
From pre-design to post-operation, NOA has the ability to guarantee the whole life cycle of the business. NOA, as an independent third-party inspection company, has a large number of domestic and international standards and specifications proficient in design, welding, non-destructive testing, painting, packaging and other fields The experienced team of professional engineers and inspection experts, with more than ten years of experience in the domestic market, is familiar with all aspects of the domestic industrial equipment supply chain, and can provide you with technical support services for the full life cycle of technical services in a timely manner, combining various products. Inspection, certification, testing, consulting, and auditing services can provide you with one-stop all-round comprehensive services.
Quality, Efficiency and Service
NOA has formed a mature and solid operation system in the development of more than 20 years. We let technical experts who are familiar with market regulations and testing standards and have professional industry experience to carry out inspection, evaluation and design review work. While meeting the requirements of domestic and international standards, we ensure that customers can obtain satisfactory service results in the first time with accurate time-sensitive management methods, and ensure that customers can seize the opportunity in the market competition.
Service Area
NOA inspection services currently cover Europe, Australia, Russia, some Middle East regions and most regions in China. NOA can ensure the consistency and continuity of customer service in different regions, and eliminate the impact of unfamiliar environments on customer quality. The guarantees and the impact of project implementation enable customers to participate in different markets across the country or around the world with flawless quality.

Tel:+86-400 821 5138

Fax:+86-21 3327 5843

Email:noa@noagroup.com

© Copyright NOA Group 版权所有 沪ICP备14042172号
Terms and Conditions
Qualification Management Formula
沪公网安备 31011502003435号